| RHH / RHW-2 90°C 2000V Aluminum Cable | ||
| Voltage: | 2000V | |
| Structure: | Conductor | Compact Stranded Aluminum Alloy (AA-8176) |
| Insulation | Cross Linked Polyethylene (XLPE) | |
| Insulation Colour | Black, Customized as needed | |
The cable is available in sizes 6 AWG through 1000 kcmil. The product is approved for use in solar power applications per the NEC article 690 and is rated 90°C for exposed or concealed wiring in wet or dry locations. Individual conductors are stranded aluminum alloy covered with a cross-linked polyethylene (XLPE) insulation and is rated for direct burial. The cable is sunlight resistant, oil resistant PRI and PRII, RoHS compliant, passes -40°C cold bend. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.
2000V
-40°C to 90°C
ASTM B836 Compact Rounded Stranded Aluminum Conductors
UL 44 Thermoset-Insulated Wires and Cables
UL 854 Service Entrance Cable
UL 4703 Standard for Photovoltaic Wire
VW-1 Vertical-Wire Flame Test (Optional)
AA 8176 Stranded Aluminum Alloy Conductors
Compact Stranded Aluminum Alloy (AA-8176)
Cross Linked Polyethylene (XLPE)
Black, Customized as needed
| Cond. Size | Conductor Number | Cond. Strands | Diameter Over Conductor (in) | Insulation Thickness (mils) | Approx. OD (in) | Aluminum Weight (lbs/1000') | Approx. Weight (lbs/1000') |
| 6 AWG | 1 | 7 | 0.169 | 85 | 0.349 | 24 | 59 |
| 4 AWG | 1 | 7 | 0.212 | 85 | 0.383 | 39 | 77 |
| 2 AWG | 1 | 6 | 0.268 | 85 | 0.438 | 62 | 104 |
| 1 AWG | 1 | 8 | 0.298 | 105 | 0.519 | 78 | 146 |
| 1/0 AWG | 1 | 10 | 0.336 | 105 | 0.546 | 99 | 164 |
| 2/0 AWG | 1 | 12 | 0.376 | 105 | 0.586 | 125 | 195 |
| 3/0 AWG | 1 | 16 | 0.422 | 105 | 0.633 | 158 | 235 |
| 4/0 AWG | 1 | 19 | 0.474 | 105 | 0.685 | 199 | 284 |
| 250 KCMIL | 1 | 22 | 0.52 | 120 | 0.76 | 235 | 350 |
| 300 KCMIL | 1 | 21 | 0.569 | 120.0 | 0.81 | 282 | 397 |
| 350 KCMIL | 1 | 35 | 0.615 | 120 | 0.856 | 329 | 462 |
| 400 KCMIL | 1 | 35 | 0.659 | 120 | 0.899 | 376 | 518 |
| 500 KCMIL | 1 | 34 | 0.735 | 120 | 0.978 | 471 | 615 |
| 600 KCMIL | 1 | 37 | 0.812 | 135 | 1.083 | 565 | 745 |
| 700 KCMIL | 1 | 58 | 0.877 | 135 | 1.147 | 659 | 851 |
| 750 KCMIL | 1 | 61 | 0.908 | 135 | 1.178 | 706 | 904 |
| 1000 KCMIL | 1 | 58 | 1.06 | 135 | 1.33 | 942 | 1168 |
SOUTH CABLE is a company specializing in the research, development, manufacturing,and sales of high-end wire and cable products.
Always a pre-production sample before mass production; Always final Inspection before shipment.
Wire, Cable
We have CSA and CUL certifications, We have Fifteen years of experience in design and development.
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR;
Accepted Payment Type:T/T,L/C,Money Gram,Western Union;Language Spoken:English,Chinese,French
Most quotes are returned within 24 hours
TEST
Tests are divided into routine tests, sampling tests and type test items.
routine tests: Tests carried out by the manufacturer on all manufactured lengths of finished cables toverify that all cables comply with specified requirements.Routine test items :Conductor resistance measurement, voltage test.
Sampling tests: Tests carried out by the manufacturer on specimens of finished cables or on certaincomponents taken from finished cables at specified frequencies to check whether the cables complywith specified requirements.
Sampling test items:Conductor inspection, dimensional inspection,thermal extension testing ofinsulation and elastomer sheaths.
Type test:Tests carried out on normal commercial principles before supply of a type of cable covered by this standard to demonstrate that the cable has satisfactory performance under the conditions of intended use.
Type testing includes electrical type testing and non-electrical type testing items.
Electrical type test items:1) Insulation resistance measurement at ambient temperature.2) Measurement of insulation resistance at maximum conductor temperature during normal operation.3) 4h voltage test.
Non-electrical type test items include insulation non-electrical type test and sheath non-electrical type test.
Insulation non-electrical type test items: Dimensional measurements、mechanical properties(tensile strength and Elongation at break)、High temperature pressure test、Low temperature performance、Thermal shock test、Thermal extension test and water absorption test, etc.
Sheath non-electrical type test items:Dimensional measurements、mechanical properties(tensile strength and Elongation at break)、High temperature pressure test、Low temperature performance、Weight loss test and thermal shock test, etc.