| AC90 600V – 3 Copper Conductors | ||
| Voltage: | 600V | |
| Structure: | Conductor | Solid Soft Copper, ASTM B3 |
| Insulation | Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free | |
| Bonding Conductor | Solid ASTM B3 Soft Bare Copper | |
| Armour | Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour | |
| Sheath Colour | 2 Core: Black White 2 Core: Black Red 3 Core: Black White Red 4 Core: Black White Red and Blue | |
AC90 armoured building wire is rated FT4-ST1 for -40°C to 90°C. Engineered specifically for demanding environments, superior flammability and smoke emission performance. For use in ventilated, non-ventilated and ladder-type cable trays. For dry locations, in ceiling air-handling plenums, exposed or concealed wiring and service entrance above ground.
600V
-40°C to 90°C
Industry compliances: CSA Standard C22.2 No. 51, No.38 and No.2256, RoHS
Flame test compliances: CSA ST1 and FT4
Solid Soft Copper, ASTM B3
Cross-linked Polyethylene (XLPE) CSA Type XL 90°C dry/wet 600V Halogen-Free
Solid ASTM B3 Soft Bare Copper
Aluminum (AIA) or Galvanized Steel (SIA) Interlock Armour
2 Core: Black White
2 Core: Black Red
3 Core: Black White Red
4 Core: Black White Red and Blue
| CONDUCTOR SIZE | GROUND SIZE | INSULATION THICKNESS | CABLE DIAMETER | CABLE WEIGHT | MAX PULLING TENSION | MIN. BEND RADIUS | AMPACITY (A) |
| 14/1 AWG | 14/1 AWG | 0.030 in. | 0.445 in. | 105 lbs/Mft | 99 lbs | 6.2 in. | 25 |
| 0.76 mm | 11.3 mm | 156 kg/km | 45 kg | 158 mm | |||
| 12/1 AWG | 14/1 AWG | 0.030 in. | 0.490 in. | 130 lbs/Mft | 157 lbs | 6.9 in. | 30 |
| 0.76 mm | 12.4 mm | 193 kg/km | 71 kg | 174 mm | |||
| 10/1 AWG | 12/1 AWG | 0.030 in. | 0.535 in. | 182 lbs/Mft | 249 lbs | 7.5 in. | 40 |
| 0.76 mm | 13.6 mm | 271 kg/km | 113 kg | 190 mm | |||
| 8/7 AWG | 10/7 AWG | 0.045 in. | 0.714 in. | 309 lbs/Mft | 418 lbs | 10.0 in. | 55 |
| 1.14 mm | 18.1 mm | 460 kg/km | 190 kg | 254 mm | |||
| 6/7 AWG | 8/7 AWG | 0.045 in. | 0.770 in. | 417 lbs/Mft | 702 lbs | 10.8 in. | 75 |
| 1.14 mm | 19.6 mm | 621 kg/km | 318 kg | 274 mm | |||
| 4/7 AWG | 8/7 AWG | 0.045 in. | 0.940 in. | 601 lbs/Mft | 1193 lbs | 13.2 in. | 95 |
| 1.14 mm | 23.9 mm | 894 kg/km | 541 kg | 334 mm | |||
| 3/7 AWG | 6/7 AWG | 0.045 in. | 0.990 in. | 721 lbs/Mft | 1622 lbs | 13.9 in. | 115 |
| 1.14 mm | 25.1 mm | 1073 kg/km | 736 kg | 352 mm | |||
| 2/7 AWG | 6/7 AWG | 0.045 in. | 1.040 in. | 891 lbs/Mft | 1922 lbs | 14.6 in. | 130 |
| 1.14 mm | 26.4 mm | 1326 kg/km | 872 kg | 370 mm |
SOUTH CABLE is a company specializing in the research, development, manufacturing,and sales of high-end wire and cable products.
Always a pre-production sample before mass production; Always final Inspection before shipment.
Wire, Cable
We have CSA and CUL certifications, We have Fifteen years of experience in design and development.
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR;
Accepted Payment Type:T/T,L/C,Money Gram,Western Union;Language Spoken:English,Chinese,French
Most quotes are returned within 24 hours
TEST
Tests are divided into routine tests, sampling tests and type test items.
routine tests: Tests carried out by the manufacturer on all manufactured lengths of finished cables toverify that all cables comply with specified requirements.Routine test items :Conductor resistance measurement, voltage test.
Sampling tests: Tests carried out by the manufacturer on specimens of finished cables or on certaincomponents taken from finished cables at specified frequencies to check whether the cables complywith specified requirements.
Sampling test items:Conductor inspection, dimensional inspection,thermal extension testing ofinsulation and elastomer sheaths.
Type test:Tests carried out on normal commercial principles before supply of a type of cable covered by this standard to demonstrate that the cable has satisfactory performance under the conditions of intended use.
Type testing includes electrical type testing and non-electrical type testing items.
Electrical type test items:1) Insulation resistance measurement at ambient temperature.2) Measurement of insulation resistance at maximum conductor temperature during normal operation.3) 4h voltage test.
Non-electrical type test items include insulation non-electrical type test and sheath non-electrical type test.
Insulation non-electrical type test items: Dimensional measurements、mechanical properties(tensile strength and Elongation at break)、High temperature pressure test、Low temperature performance、Thermal shock test、Thermal extension test and water absorption test, etc.
Sheath non-electrical type test items:Dimensional measurements、mechanical properties(tensile strength and Elongation at break)、High temperature pressure test、Low temperature performance、Weight loss test and thermal shock test, etc.